PRODUCT
The wind electric heater is a simple introduction - bearing, a fixed axle bearing knowledge
by:Waxing
2020-06-20
One, two.
5 -
6 megawatts fixed axle bearing heater introduction & emsp;
Beijing Jin Yu can electric appliance co. , LTD successively for several car company in the production of medium frequency induction heater.
Applied to 2.
5 -
6 megawatts bearing, axis of hot charging, completely meet the use requirements, recognized by users.
Second, the technical parameters & emsp;
1, model: JYN -
ZDC50*2
2, working voltage: ac 380 v, A phase B phase C and N facies (
The zero line)
;
3, power: 100 kw;
4, working frequency: 50 ~ 60 hz;
5, control cabinet size: 1000 mm * 650 mm * 2100 mm;
6, heating ring size: custom & emsp;
About 300 kg; 7, the overall quality of equipment:
8, K type thermocouple temperature measurement range: -
200℃-
1300℃;
9, suitable artifacts: 2.
5 -
6 mw bearing, axis & emsp;
With double power source can meet two workpiece heat at the same time.
Part three, the control instructions & emsp;
1, start heating.
If select automatic control mode, select the touch screen '' to start the automatic heating equipment began to heat;
If select manual control mode, select the touch screen 'manual start outer heating' and '' manually start the inner ring heating equipment began to heat;
2, PLC control.
Select automatic control mode, the heating process can control temperature, when reaches a certain temperature, the device will stop heating waiting, until heated to a set temperature, open heat preservation mode, heat insulation for a period of time after the alarm prompt is complete;
3, if a fault occurs in the process of equipment operation, failure will be conducted on a touch screen display, please check the alarm content, and then to solve, troubleshooting in the 'reset' button after eliminating the police.
The equipment operation is simple, touch screen display completely the whole heating process.
The mitsubishi PLC, Siemens touch screen.
Four, equipment installation and maintenance & emsp;
Because the device heating coil is large, is not easy to transport.
USES the on-site installation, commissioning equipment.
At the scene to guide use heaters, and in accordance with the requirements under the simple change process, follow up a bearing hot charging.
In the later use process such as heater failure response time is less than 24 hours, no more than 48 hours to the scene.
Heater pictures at the same time heating bearing and shaft
Custom message