Motorized spindle 5 main problem and correct disposal methods
by:Waxing2020-11-14
1, main shaft stuck, unable to rotate the fault reason: a, spindle bearing is wear, have sundry infarction, bearing jammed;
B, dust ring before and after the dust ring gap with foreign body between the infarction.
Fault disposal: please send back to our main shaft to stop overhaul.
2, chuck can't lock incurred out of knife, cutting knife reason: rotor front cone is damaged, chuck appearance deformation and damage.
Fault disposal: please send back to our main shaft to stop cone grinding, damaged chuck cannot continue to use.
3, in the process of using the spindle temperature through high fault reason: spindle used for a long time, don't do a good cooling measures;
Bearing damage.
Problem disposal: completes the spindle cooling measures, initiative using thermal water cooling machine and fixture for the main shaft to stop cooling;
Send back to our main shaft of stopped dismantling overhaul.
4, main shaft wall, but the inverter appear there is power output fault reason: may be the phase voltage imbalance.
Fault disposal: check the lines to the spindle and drive, drive and frequency converter cohesion can be good.
5, spindle stalling, unable to start trouble reason: a, may be a spindle stator winding burn out, or coil varnish ablation.
B, check the inverter fault information, whether inverter braking.
After fault disposal: first of all, the multimeter measurement of spindle end socket UVW resistance can balance between three pin;
Then check that the use of the environment, whether using filtering and regulating the installation of the seal gas stop filtering and regulating;
Check the inverter parameters Settings, adjust frequency converter parameters.
If value is not balanced, can be sure to stator coil burned;
To stop repair spindle return card west Germany.
sycotec 4025 sycotec 4033